Upgrade a production system in the order below. Profinity 2.3 changes where data is stored, how security is configured, which features need a licence, and how the REST API reports errors, so read the breaking changes first.

Before you start, take the backup in step 1, and test the upgrade on a non-production instance if you can.

  1. Back up the config/ and profiles/ folders of the artefacts directory, together with license/ and certificates/. These folders are named Config and Profiles until 2.3 starts for the first time. On a 2.2 system the artefacts directory is %LOCALAPPDATA%\Prohelion\Profinity on Windows, ~/Library/Application Support/Prohelion/Profinity on macOS, and ~/.local/share/Prohelion/Profinity on Linux.
  2. Install Profinity 2.3 and start it once. The first start moves data from older locations into the 2.3 artefacts directory, renames Config, Profiles, and Logs to lowercase, and rewrites security.yaml and profile.yaml in the 2.3 camelCase format when it loads them. It rewrites config.yaml on that first load when the file still has legacy Pascal keys or an older version stamp. Profinity does not move data when PROFINITY_HOME is set, so copy anything you need into that location yourself.
  3. Open ADMIN > License and confirm the state and the edition. A 2.2 installation upgraded without a licence file is unlicensed once any trial ends, and remote web access, user and role administration, two-factor authentication, Profinity AI, and the Email, Slack, Webhook, and MQTT rule actions stop being available until you upload a licence. Refer to Apply a licence and Licensing.
  4. Sign in as an administrator, open ADMIN > Users & Groups, and check the Roles tab and each user's assigned roles. Change the default admin password if you have not already. A default admin account that Profinity creates must change its password at first sign-in.
  5. Open ADMIN > System Configuration and confirm the Sign-in method, the password policy, and the SSO, SCIM, and SIEM settings.
  6. Open ADMIN > Logs and read the messages from first start. On Linux, the migration messages name each file that moved.
  7. Open each custom dashboard in the dashboard editor and confirm it loads without schema errors.
  8. Unlock the firmware of each Gen2 battery management system once, and enter its passcode again, because 2.3 does not keep passcodes in the profile.
  9. Run every integration that calls /api/v2 against a test instance, because error responses changed. Refer to REST API errors.
  10. Open each BACnet component and set Device instance to the instance of its device, because Profinity now checks it. Refer to BACnet device instance.

To return to 2.2, reinstall 2.2 and restore the backup you took in step 1.

Linux and Docker data locations

On Linux, 2.3 moves data from ~/.local/share/Prohelion/Profinity, the 2.2 location, to /var/lib/prohelion/profinity the first time it starts. A Docker container follows the same rule unless PROFINITY_HOME is set, and the Docker compose file Prohelion publishes sets it to the container path that holds your mounted data.

For a Docker upgrade, set PROFINITY_HOME to the container path of your existing mount, keep that mount, and copy any legacy Config and Profiles folders into it before you start the 2.3 image. Refer to Docker installation.