Performance
Calculations:
L = N2 x AL = 362turns x 37nH/turn = 48µH
Testing:
50A step response:
L = 118V / (23.4A / 10 µS) = 50µH
100A step response:
Start of step (10A) L = 118V / (45.3A / 19.2µS) = 50µH
End of step (115A) L = 118V / (35.9A / 12.4µS) = 40µH
120A Step response:
Start of step (10A) L = 118V / (54.7A / 23.8µS) = 50µH
End of step (150A) L = 118V / (54.7A / 13.8µS) = 30µH
The decay of inductance with increasing current is gradual and continuous, unlike the ferrite cored CSIRO inductors. This gradual decay presents no major problems for the WaveSculptor current control loop maintaining control of the motor phase current.