Messages and Signals

This section provides information on the CAN bus messages and signals used in the ProhelionBmsD1000Gen2. Each message is identified by its unique ID, and the structure, including signals, is described.

Note! "Default BASE ID" The following Message IDs assume a default CAN Bus BASE ID of 0x600. The BASE ID of each device is configurable via the device configuration. If the BASE ID has been configured differently on the device, make sure to account for the shift in the Message IDs. The Message ID offsets from the BASE ID will remain the same regardless of the device configuration.

Contents

Message ID Name
0x600 Device Heartbeat
0x601 Device Firmware Info
0x606 BMS Info
0x607 BMS Current Data
0x608 BMS Voltage Data
0x609 BMS Auxiliary Data
0x60a BMS SoC Data
0x60c BMS SoP Data
0x60d Node Info
0x60e Node Cell Info
0x60f Node Temp Info
0x610 Nodeđť’©Voltage Info
0x611 Nodeđť’©Cell Voltages 1
0x612 Nodeđť’©Cell Voltages 2
0x613 Nodeđť’©Cell Voltages 3
0x614 Nodeđť’©Cell Voltages 4
0x615 Nodeđť’©Cell Temps
0x616 Nodeđť’©Stats
0x617 Nodeđť’©Diagnostics
0x6f0 Contactor Diagnostics
0x6f1 Device Watchdog Info
0x6f2 Device Selftest Info
0x6f3 Node Diagnostics
0x6f4 Node Stats
0x6f5 Node Cell Stats
0x6f6 Node Temp Stats
0x6f7 Node Status Registers
0x6f8 Sensor Data 1
0x6f9 Sensor Data 2

DeviceHeartbeat

  • ID: 0x600 (1536)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Device heartbeat information
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
DeviceType Type of device in the system 0 32 False 1 0 N/A N/A little_endian
DeviceSerial Unique serial number of the device 32 32 False 1 0 N/A N/A little_endian

DeviceFirmwareInfo

  • ID: 0x601 (1537)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Firmware version information
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
FirmwareMajorVersion Major version of firmware 0 8 False 1 0 N/A N/A little_endian
FirmwareMinorVersion Minor version of firmware 8 8 False 1 0 N/A N/A little_endian
FirmwarePatchVersion Patch version of firmware 16 16 False 1 0 N/A N/A little_endian
FirmwareBuildNumber Commit hash of firmware 32 32 False 1 0 N/A N/A little_endian

BMSInfo

  • ID: 0x606 (1542)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Information on BMS states, failures, and faults
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
BMSStateINIT Initialisation state. Immediately enters this state on startup and proceeds to CALIBRATE once the conditions are met 0 1 False 1 0 N/A N/A little_endian
BMSStateCALIBRATE Calibration state. Ensures contactors are open before moving to the SAFE state. 1 1 False 1 0 N/A N/A little_endian
BMSStateIDLE Idle state. System is healthy and awaiting a command to enable or charge. 2 1 False 1 0 N/A N/A little_endian
BMSStateCONNECT Connect state. A request has been made to close the load contactors. The negative contactor to the load has been closed to enable load voltage checks. 3 1 False 1 0 N/A N/A little_endian
BMSStatePRECHARGE Precharge state. The precharge contactor is closed. 4 1 False 1 0 N/A N/A little_endian
BMSStateENABLED Enabled state. Contactors to the load are now closed following a successful PRECHARGE state. This state will persist until commanded otherwise, or a fault occurs. 5 1 False 1 0 N/A N/A little_endian
BMSStateCHARGE_INIT Charge initialise state. Initialises the charge session, including EVCC for EVSE charging if configured. Waits for Charge Enable Command to proceed 6 1 False 1 0 N/A N/A little_endian
BMSStateCHARGE_CONNECT Charge connect state. Closes the negative charge contactor and checks that battery and charger voltages match before proceeding 7 1 False 1 0 N/A N/A little_endian
BMSStateCHARGE_ENABLED Charge enabled state. Closes the positive charge contactor, allowing the charger to deliver current to the battery 8 1 False 1 0 N/A N/A little_endian
BMSStateCHARGE_STOPPING Charge stopping state. Waits for current flow to reduce before opening the contactors and performing welding detection 9 1 False 1 0 N/A N/A little_endian
BMSStateDISCONNECT Safe disconnect state. This state is a transitionary state to allow current flow to stop prior to opening the contactors in the SAFE state. This state occurs if an error has occurred while contactors are closed 10 1 False 1 0 N/A N/A little_endian
BMSStateSAFE Safe state. An error has occurred or we have progressed from the CALIBRATE state. The SAFE state ensures the battery is disconnected from the load and will transition to IDLE state after all errors have cleared. Latching errors will require a reset before the BMS will leave SAFE state 11 1 False 1 0 N/A N/A little_endian
BMSPrechargeFailTIMEOUT Timeout issue. State has timed out waiting for successful completion of the precharge process 16 1 False 1 0 N/A N/A little_endian
BMSPrechargeFailOVERCURRENTMAX Over-current maximum detected 17 1 False 1 0 N/A N/A little_endian
BMSPrechargeFailOVERCURRENTPCHG Over-current during precharge. Current flow during precharge is abnormally high. Check configuration 18 1 False 1 0 N/A N/A little_endian
BMSPrechargeFailNEGCURRENT Negative current detected. Current is flowing into the pack instead of into the load 19 1 False 1 0 N/A N/A little_endian
BMSPrechargeFailSTABLECURRENT Stable current issue. Current flow through the precharge circuit is expected to decrease as the load voltage rises to the battery voltage 20 1 False 1 0 N/A N/A little_endian
BMSPrechargeFailOVERVOLTAGE Over-voltage detected. Voltage greater than expected 21 1 False 1 0 N/A N/A little_endian
BMSPrechargeFailSTABLEVOLTAGE Stable voltage issue. Load voltage is expected to rise to battery voltage 22 1 False 1 0 N/A N/A little_endian
BMSContactorFaultCONTACTOR1 Contactor 1 fault 24 1 False 1 0 N/A N/A little_endian
BMSContactorFaultCONTACTOR2 Contactor 2 fault 25 1 False 1 0 N/A N/A little_endian
BMSContactorFaultCONTACTOR3 Contactor 3 fault 26 1 False 1 0 N/A N/A little_endian
BMSContactorFaultCONTACTOR4 Contactor 4 fault 27 1 False 1 0 N/A N/A little_endian
BMSContactorFaultCONTACTOR5 Contactor 5 fault 28 1 False 1 0 N/A N/A little_endian
BMSReasonSELFTESTFAIL Self-test failure. Internal memory or peripheral checks are failing indicating a fault may be present in the microprocessor 32 1 False 1 0 N/A N/A little_endian
BMSReasonWATCHDOGFAIL Watchdog failure. A module within the firmware is not updating as expected 33 1 False 1 0 N/A N/A little_endian
BMSReasonCONTACTORFAIL Contactor failure. Contactor states presented by auxiliary circuits do not match the intended state 34 1 False 1 0 N/A N/A little_endian
BMSReasonHVIL HVIL issue. The interlocked loop is measuring high impedance, indicating a connector failure 35 1 False 1 0 N/A N/A little_endian
BMSReasonBATTVOLTAGE Battery voltage issue. Battery voltage is out of expected ranges 36 1 False 1 0 N/A N/A little_endian
BMSReasonPACKVOLTAGE Pack voltage issue. Pack voltage is not aligned with the sum of the measured cell voltages, indicating a loose cell node connection 37 1 False 1 0 N/A N/A little_endian
BMSReasonLOADVOLTAGE Load voltage issue. The load voltage is out of expected ranges 38 1 False 1 0 N/A N/A little_endian
BMSReasonCHARGERVOLTAGE Charger voltage issue. The charging equipment voltage is out of expected ranges 39 1 False 1 0 N/A N/A little_endian
BMSReasonOVERCURRENT Over-current detected. Software over-current detection indicating current has risen above configured limits 40 1 False 1 0 N/A N/A little_endian
BMSReasonNODECOUNT Node count issue. Incorrect number of CMU (Nodes) detected by the BMS 41 1 False 1 0 N/A N/A little_endian
BMSReasonCELLCOUNT Cell count issue. Incorrect number of cells detected by the CMU nodes 42 1 False 1 0 N/A N/A little_endian
BMSReasonTEMPCOUNT Temperature count issue. Incorrect number of temperature sensors detected by the CMU nodes 43 1 False 1 0 N/A N/A little_endian
BMSReasonBJU BJU timeout. BJU has not responded to requests for measurements 44 1 False 1 0 N/A N/A little_endian
BMSReasonIO Pack timeout. IO expander is not responding on the I2C bus 45 1 False 1 0 N/A N/A little_endian
BMSReasonCONTROLTIMEOUT Control timeout. BMS has not received a control command for a number of seconds. 46 1 False 1 0 N/A N/A little_endian
BMSReasonINTERNALCOMMS Internal Comms issue. A device connected to the BMS is not responding 47 1 False 1 0 N/A N/A little_endian
BMSReasonOVERVOLT Cell over-voltage detected 48 1 False 1 0 N/A N/A little_endian
BMSReasonUNDERVOLT Cell under-voltage detected 49 1 False 1 0 N/A N/A little_endian
BMSReasonOVERTEMP Cell over-temperature detected 50 1 False 1 0 N/A N/A little_endian
BMSReasonUNDERTEMP Cell under-temperature detected 51 1 False 1 0 N/A N/A little_endian
BMSReasonPRESSURE Pressure issue 52 1 False 1 0 N/A N/A little_endian
BMSReasonHUMIDITY Humidity issue 53 1 False 1 0 N/A N/A little_endian
BMSReasonVOC VOC (Volatile Organic Compounds) issue 54 1 False 1 0 N/A N/A little_endian
BMSReasonNOX NOx (Nitrogen Oxides) issue 55 1 False 1 0 N/A N/A little_endian
BMSReasonPRECHARGE Precharge failure 56 1 False 1 0 N/A N/A little_endian

BMSCurrentData

  • ID: 0x607 (1543)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Current measurement data.
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
InstantaneousCurrent Instantaneous current measurement A 0 32 True 0.001 0 N/A N/A little_endian
FilteredCurrent Filtered current measurement A 32 32 True 0.001 0 N/A N/A little_endian

BMSVoltageData

  • ID: 0x608 (1544)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Voltage measurement data.
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
BatteryVoltage Battery voltage measurement V 0 32 True 0.001 0 N/A N/A little_endian
LoadVoltage Load voltage measurement V 32 32 True 0.001 0 N/A N/A little_endian

BMSAuxiliaryData

  • ID: 0x609 (1545)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Auxiliary data.
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
AuxiliaryVoltage Auxiliary voltage measurement V 0 32 True 0.001 0 N/A N/A little_endian
Power Power measurement W 32 32 True 0.001 0 N/A N/A little_endian

BMSSoCData

  • ID: 0x60a (1546)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Battery SoC estimations
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
SoCPercentage Battery SoC Percentage % 0 16 False 0.1 0 N/A N/A little_endian
SoCCapacity Battery SoC in Ah Ah 16 16 False 0.1 0 N/A N/A little_endian
OCV_mV Estimated Open Circuit Voltage in mV V 32 16 False 0.001 0 N/A N/A little_endian
SoHPercentage Estimated SoH Percentage % 48 16 False 0.1 0 N/A N/A little_endian

BMSSoPData

  • ID: 0x60c (1548)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: State of Power Information
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
SoPMaxCurrentDischarge Max Allowable Discharge Current A 0 32 True 0.001 0 N/A N/A little_endian
SoPMaxCurrentCharge Max Allowable Charge Current A 32 32 True 0.001 0 N/A N/A little_endian

NodeInfo

  • ID: 0x60d (1549)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Node information
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
TotalPackVoltage Total pack voltage measurement V 0 32 False 0.001 0 N/A N/A little_endian
PackBalanceThreshold Pack balance threshold measurement V 32 16 False 0.001 0 N/A N/A little_endian
TotalCellsBalancing Total cells balancing status 48 16 False 1 0 N/A N/A little_endian

NodeCellInfo

  • ID: 0x60e (1550)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Cell Voltage Statistics
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
MaxCellVoltage Maximum cell voltage measurement V 0 16 False 0.001 0 N/A N/A little_endian
MaxCellVoltageNodeID Node ID for max cell voltage 16 8 False 1 0 N/A N/A little_endian
MaxCellVoltageCellID Cell ID for max cell voltage 24 8 False 1 0 N/A N/A little_endian
MinCellVoltage Minimum cell voltage measurement V 32 16 False 0.001 0 N/A N/A little_endian
MinCellVoltageNodeID Node ID for min cell voltage 48 8 False 1 0 N/A N/A little_endian
MinCellVoltageCellID Cell ID for min cell voltage 56 8 False 1 0 N/A N/A little_endian

NodeTempInfo

  • ID: 0x60f (1551)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Cell Temperature Statistics
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
MaxTemperature Maximum temperature measurement C 0 16 True 0.1 0 N/A N/A little_endian
MaxTemperatureNodeID Node ID for max temperature 16 8 False 1 0 N/A N/A little_endian
MaxTemperatureSensorID Sensor ID for max temperature 24 8 False 1 0 N/A N/A little_endian
MinTemperature Minimum temperature measurement C 32 16 True 0.1 0 N/A N/A little_endian
MinTemperatureNodeID Node ID for min temperature 48 8 False 1 0 N/A N/A little_endian
MinTemperatureSensorID Sensor ID for min temperature 56 8 False 1 0 N/A N/A little_endian

Node𝒩VoltageInfo

Note! For brevity, node messages are described once, where 𝒩 describes the node number (up to a maximum of 32 nodes).

  • ID: 0x610 + (𝒩 × 0x7)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Voltage information of the node
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
Node𝒩TotalVoltage Sum of the voltage of the cells in the node V 0 32 False 0.001 0 N/A N/A little_endian
Node𝒩HighResistanceCellSense Indication that a cell is reading high resistance 48 16 False 1 0 N/A N/A little_endian

Node𝒩CellVoltages1

Note! For brevity, node messages are described once, where 𝒩 describes the node number (up to a maximum of 32 nodes).

  • ID: 0x611 + (𝒩 × 0x7)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Node cell voltage measurements (1 of 4)
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
Node𝒩Cell01 Cell 01 measured voltage V 0 16 False 0.001 0 N/A N/A little_endian
Node𝒩Cell02 Cell 02 measured voltage V 16 16 False 0.001 0 N/A N/A little_endian
Node𝒩Cell03 Cell 03 measured voltage V 32 16 False 0.001 0 N/A N/A little_endian
Node𝒩Cell04 Cell 04 measured voltage V 48 16 False 0.001 0 N/A N/A little_endian

Node𝒩CellVoltages2

Note! For brevity, node messages are described once, where 𝒩 describes the node number (up to a maximum of 32 nodes).

  • ID: 0x612 + (𝒩 × 0x7)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Node cell voltage measurements (2 of 4)
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
Node𝒩Cell05 Cell 05 measured voltage V 0 16 False 0.001 0 N/A N/A little_endian
Node𝒩Cell06 Cell 06 measured voltage V 16 16 False 0.001 0 N/A N/A little_endian
Node𝒩Cell07 Cell 07 measured voltage V 32 16 False 0.001 0 N/A N/A little_endian
Node𝒩Cell08 Cell 08 measured voltage V 48 16 False 0.001 0 N/A N/A little_endian

Node𝒩CellVoltages3

Note! For brevity, node messages are described once, where 𝒩 describes the node number (up to a maximum of 32 nodes).

  • ID: 0x613 + (𝒩 × 0x7)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Node cell voltage measurements (3 of 4)
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
Node𝒩Cell09 Cell 09 measured voltage V 0 16 False 0.001 0 N/A N/A little_endian
Node𝒩Cell10 Cell 10 measured voltage V 16 16 False 0.001 0 N/A N/A little_endian
Node𝒩Cell11 Cell 11 measured voltage V 32 16 False 0.001 0 N/A N/A little_endian
Node𝒩Cell12 Cell 12 measured voltage V 48 16 False 0.001 0 N/A N/A little_endian

Node𝒩CellVoltages4

Note! For brevity, node messages are described once, where 𝒩 describes the node number (up to a maximum of 32 nodes).

  • ID: 0x614 + (𝒩 × 0x7)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Node cell voltage measurements (4 of 4)
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
Node𝒩Cell13 Cell 13 measured voltage V 0 16 False 0.001 0 N/A N/A little_endian
Node𝒩Cell14 Cell 14 measured voltage V 16 16 False 0.001 0 N/A N/A little_endian

Node𝒩CellTemps

Note! For brevity, node messages are described once, where 𝒩 describes the node number (up to a maximum of 32 nodes).

  • ID: 0x615 + (𝒩 × 0x7)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Node thermistor temperature measurements
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
Node𝒩Temp01 Thermistor 01 temperature measurement C 0 16 True 0.1 0 N/A N/A little_endian
Node𝒩Temp02 Thermistor 02 temperature measurement C 16 16 True 0.1 0 N/A N/A little_endian
Node𝒩Temp03 Thermistor 03 temperature measurement C 32 16 True 0.1 0 N/A N/A little_endian
Node𝒩Temp04 Thermistor 04 temperature measurement C 48 16 True 0.1 0 N/A N/A little_endian

Node𝒩Stats

Note! For brevity, node messages are described once, where 𝒩 describes the node number (up to a maximum of 32 nodes).

  • ID: 0x616 + (𝒩 × 0x7)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Node cell statistics
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
Node𝒩ConnectedCells Number of cells detected on the node 0 8 False 1 0 N/A N/A little_endian
Node𝒩DisconnectedCells Number of cells that are configured but not detected on the node 8 8 False 1 0 N/A N/A little_endian
Node𝒩ConnectedTempSensors Number of connected thermistors on the node 16 8 False 1 0 N/A N/A little_endian
Node𝒩DisconnectedTempSensors Number of thermistors that are configured but not detected on the node 24 8 False 1 0 N/A N/A little_endian
Node𝒩CellBalanceCommandSent Cell balance command has been send to the node 32 16 False 1 0 N/A N/A little_endian
Node𝒩CellBalanceStatus Status of cell balancing on the node 48 16 False 1 0 N/A N/A little_endian

Node𝒩Diagnostics

Note! For brevity, node messages are described once, where 𝒩 describes the node number (up to a maximum of 32 nodes).

  • ID: 0x617 + (𝒩 × 0x7)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Node diagnostics
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
Node𝒩Type Type of the node 0 8 False 1 0 N/A N/A little_endian
Node𝒩Address Address of the node 8 8 False 1 0 N/A N/A little_endian
Node𝒩UARTResult Latest result of UART communications 16 16 False 1 0 N/A N/A little_endian
Node𝒩State State of the node 32 16 False 1 0 N/A N/A little_endian
Node𝒩StateTimer Time node has spent in the current state 48 16 False 1 0 N/A N/A little_endian

ContactorDiagnostics

  • ID: 0x6f0 (1776)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Contactor diagnostics information
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
ContactorDesiredState Intended state of the contactors 0 32 False 1 0 N/A N/A little_endian
ContactorActualState Actual state of the contactors 32 32 False 1 0 N/A N/A little_endian

DeviceWatchdogInfo

  • ID: 0x6f1 (1777)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Information relating to internal watchdog status
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
SelfTestTaskStatus Self test task running state
  • 4: Fail
  • 2: Fast
  • 1: Slow
  • 0: Ok
0 4 False 1 0 N/A N/A little_endian
SensorTaskStatus Sensor task running state
  • 4: Fail
  • 2: Fast
  • 1: Slow
  • 0: Ok
8 8 False 1 0 N/A N/A little_endian
TelemetryTaskStatus Telemetry task running state
  • 4: Fail
  • 2: Fast
  • 1: Slow
  • 0: Ok
16 8 False 1 0 N/A N/A little_endian
CMUTaskStatus CMU task running state
  • 4: Fail
  • 2: Fast
  • 1: Slow
  • 0: Ok
24 8 False 1 0 N/A N/A little_endian
BMSTaskStatus BMS task running state
  • 4: Fail
  • 2: Fast
  • 1: Slow
  • 0: Ok
32 8 False 1 0 N/A N/A little_endian
SoXTaskStatus SoX task running state
  • 4: Fail
  • 2: Fast
  • 1: Slow
  • 0: Ok
40 8 False 1 0 N/A N/A little_endian
WatchdogReset State of the watchdog peripheral
  • 1: Fail
  • 0: Ok
48 1 False 1 0 N/A N/A little_endian

DeviceSelftestInfo

  • ID: 0x6f2 (1778)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Result of various internal self testing
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
SelftestResult Reserved 0 64 False 1 0 N/A N/A little_endian

NodeDiagnostics

  • ID: 0x6f3 (1779)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: CMU controller diagnostic information
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
ControllerType Type of the CMU controller 0 8 False 1 0 N/A N/A little_endian
CurrentState State of the CMU controller 8 8 False 1 0 N/A N/A little_endian
CurrentStateTimer Time the controller has spent in the current state 16 16 False 1 0 N/A N/A little_endian
CommsResult Latest result of the CMU controller <--> CMU communication 32 16 False 1 0 N/A N/A little_endian

NodeStats

  • ID: 0x6f4 (1780)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Node statistics information
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
TotalConfiguredNodes Sum of nodes expected in the configuration 0 16 False 1 0 N/A N/A little_endian
TotalConnectedNodes Sum of nodes detected by the controller 16 16 False 1 0 N/A N/A little_endian
TotalDisconnectedNodes Sum of configured nodes not detected by the controller 32 16 False 1 0 N/A N/A little_endian

NodeCellStats

  • ID: 0x6f5 (1781)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Cell statistics information
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
TotalConfiguredCells Sum of cells expected in the configuration 0 16 False 1 0 N/A N/A little_endian
TotalConnectedCells Sum of cells detected by all nodes 16 16 False 1 0 N/A N/A little_endian
TotalDisconnectedCells Sum of configured cells not detected by all nodes 32 16 False 1 0 N/A N/A little_endian

NodeTempStats

  • ID: 0x6f6 (1782)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Thermistor statistics information
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
TotalConfiguredTempSensors Sum of thermistors expected in the configuration 0 16 False 1 0 N/A N/A little_endian
TotalConnectedTempSensors Sum of thermistors detected by all nodes 16 16 False 1 0 N/A N/A little_endian
TotalDisconnectedTempSensors Sum of configured thermistors not detected by all nodes 32 16 False 1 0 N/A N/A little_endian

NodeStatusRegisters

  • ID: 0x6f7 (1783)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Node controller status registers
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
RXStatus Node controller RX status register 0 8 False 1 0 N/A N/A little_endian
TXStatus Node controller TX status register 8 8 False 1 0 N/A N/A little_endian
LSSMByteHWError HW error reported by node controller BOOLEAN 16 1 False 1 0 N/A N/A little_endian
LSSMByteAliveCNTError Incorrect alive count reported by node controller BOOLEAN 17 1 False 1 0 N/A N/A little_endian
LSSMByteCommandOP Current command OP code BOOLEAN 18 1 False 1 0 N/A N/A little_endian
LSSMByteCommMismatchError Communication mismatch error reported BOOLEAN 19 1 False 1 0 N/A N/A little_endian
LSSMByteAlertPacketError Packet error reported BOOLEAN 20 1 False 1 0 N/A N/A little_endian
LSSMByteCommError Comm error reported BOOLEAN 21 1 False 1 0 N/A N/A little_endian
LSSMByteAlertPacketStatusError Packet status error reported BOOLEAN 22 1 False 1 0 N/A N/A little_endian
LSSMByteRXReady Node controller ready to receive BOOLEAN 23 1 False 1 0 N/A N/A little_endian
GENStatus 24 8 False 1 0 N/A N/A little_endian
OPStateStatus 32 8 False 1 0 N/A N/A little_endian
BufferStatus 40 8 False 1 0 N/A N/A little_endian
WatchdogStatus 48 8 False 1 0 N/A N/A little_endian
GPIOStatus 56 8 False 1 0 N/A N/A little_endian

SensorData1

  • ID: 0x6f8 (1784)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Sensor data 1
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
Temperature1 Thermistor 1 measured temperature C 0 16 True 0.1 0 N/A N/A little_endian
Temperature2 Thermistor 2 measured temperature C 16 16 True 0.1 0 N/A N/A little_endian
Pressure Measured pressure kPa 32 16 True 0.1 0 N/A N/A little_endian
Humidity Measured humidity % RH 48 16 True 0.1 0 N/A N/A little_endian

SensorData2

  • ID: 0x6f9 (1785)
  • Length: 8
  • Senders: ProhelionBmsD1000Gen2
  • Comment: Sensor data 2
Name Comment                             Unit Start Bit Length Signed Scale Offset Min Max Byte Order
VOC Measured Volatile Organic Compound (VOC) concentration in parts per billion (ppb) ppb 0 16 False 1 0 N/A N/A little_endian
NOX Measured Nitrous Oxide (NOx) concentration in parts per billion (ppb) ppb 16 16 False 1 0 N/A N/A little_endian