This section documents the software and firmware related behaviours, configuration, and telemetry specifications of the 48V BMS.

The Prohelion 48V BMS firmware uses a finite state machine to control the outputs of the BMS. The finite state machine consists of a set of BMS states in which the BMS can operate. Each state can transition to another state through a set of transitions. Transitions can be triggered by combinations of BMS events.

The diagram below shows the operational behaviour of the BMS State Machine. It shows each of the states and all the transitions between the states.

Figure 11: BMS State Machine

Figure 11: BMS State Machine

BMS Outputs

The BMS state machine can control the following outputs to safely manage the battery pack.

Output Description
Precharge This output enables the pre-charge MOSFET to enable the battery to discharge through the pre-charge resistor
The pre-charge circuit allows for capacitive loads to be charged up to the battery voltage through a resistor in a controlled manner. This prevents high inrush currents which may cause damage to the cells, BMS and loads.
Discharge This output enables the discharge MOSFET array which allows current to flow from the battery and into a load (conventional current flow). This will allow the battery to be discharged.
Charge This output enables the charge MOSFET array which allows current to flow from the load and into the battery (conventional current flow). This will allow the battery to be charged.
Balance This output is a virtual output which signals to other firmware modules that cell balancing is allowed in the current state. The other firmware modules will perform additional checks to ensure that balancing is only enabled when it is safe and necessary to balance the individual cell State of Charges using the balance resistors. It is important to note that all balance resistors may be disabled while the balance output may be on.

BMS States

The BMS state machine consists of the following finite states. Each state defines the set of outputs which should be enabled when the BMS is in that state.

ID State Description Outputs
S0 INIT The initialisation state All outputs off
S1 PRECHARGE Pre-Charge State PRECHARGE On
S2 DISCHARGE ENABLED Discharge enabled state DISCHARGE On
BALANCE On
S3 CHARGE ENABLED Charge enabled state CHARGE On
Balancing On
S4 ALL ENABLED All enabled state DISCHARGE On
CHARGE On
BALANCE On
S5 DISCHARGE ENABLED PRE Discharge enabled state with Precharge DISCHARGE On
PRECHARGE On
S6 CHARGE ENABLED PRE Charge enabled state with Precharge CHARGE On
PRECHARGE On
S7 ALL ENABLED PRE All enabled state with Precharge DISCHARGE On
PRECHARGE On
S99 ERROR Error State All Outputs off

BMS Events

The BMS state machine can be triggered by several internal events. Each event is a Boolean flag that can be either true (set) or false (cleared) by submodules in the BMS firmware. There are two types of events that the BMS state machine uses:

  • The BMS state machine can be triggered by several internal events. Each event is a Boolean flag that can be either true (set) or false (cleared) by submodules in the BMS firmware. There are two types of events that the BMS state machine uses:
    • Normal – Events of this type will be set when a condition is present and will automatically be cleared if the condition that is causing the event has corrected itself and the event is no longer present.
    • Latching – Events of this type will be set by a condition and will remain set until the event has been explicitly cleared by the user or the BMS has been rebooted.
HEX Value Event Event Type Description
0x100 CALIBRATED This indicates that the BMS has been calibrated and issued a valid serial number
0x200 CONNECTED This indicates that the BMS is connected to a CAN bus network and is receiving messages on the configured CAN Switches ID
0x400 STANDALONE This indicates that the Standalone BMS Mode is enabled
0x800 SENSE ERROR This indicates that there is a low-level sense error with the communication to the cell monitoring nodes
0x1000 OVER VOLT This indicates that one or more cell voltages have exceeded the configured Cell Over Voltage Threshold
0x2000 UNDER VOLT This indicates that one or more cell voltages have exceeded the configured Cell Under Voltage Threshold
0x4000 OVER TEMP This indicates that one or more cell temperatures have exceeded the configured Over Temperature Threshold
0x8000 UNDER TEMP This indicates that one or more cell temperatures have configured Cell Under Temperature Threshold
0x10000 CRITICAL OVER CURRENT Latching This indicates that charge or discharge current has exceeded the configured Critical Over Current Threshold
0x20000 CRITICAL OVER VOLT Latching This indicates that one or more cell voltages have exceeded the configured Critical Cell Over Voltage Threshold
0x40000 CRITICAL UNDER VOLT Latching This indicates that one or more cell voltages have exceeded the configured Critical Cell Under Voltage Threshold
0x80000 BALANCING This indicates that one or more cells are currently balancing
0x100000 PACK PRECHARGE FAIL This indicates the difference (delta) between the Load Voltage and the Battery Voltage is not within the configured Precharge Voltage Delta
0x400000 PACK ENABLE This indicates that the BMS is receiving the command to enable the pack and move into a state which allows charge, discharge or both outputs.
0x800000 SoCINVALID This indicates that the current SoCestimation is invalid

BMS State Transitions

The BMS state machine contains several state transitions. Each transition contains a current state, next state, a set of events and an event check type. The state transition will only proceed to the next state if the BMS state machine is in the current state and the event check has been satisfied.

There are three Event Check Types which can be used to check the list of events for each transition:

  • All – Logical AND – All events being set (true) will trigger the state transition.
  • Any – Logical OR – Any event being set (true) will trigger the state transition.
  • None – Logical NOT (OR) - All events being cleared (false) will trigger the state transition (No events can be set)

The BMS CRITICAL SAFETY EVENTS is a group of events that are considered safety critical and should result in the BMS moving into an ERROR state from ANY state. This group which consists of the following events:

  • CRITICAL OVER VOLT
  • CRITICAL UNDER VOLT
  • CRITICAL OVER CURRENT
  • PACK PRECHARGE FAIL

Below is the BMS state machine transition table:

ID Current State Next State Event Check Type Events
T0 ANY ERROR ANY BMS CRITICAL SAFETY EVENTS
T1 ERROR INIT NONE BMS CRITICAL SAFETY EVENTS
T2 INIT PRECHARGE ANY PACK ENABLE
STANDALONE
T3 PRECHARGE ERROR ANY PACK PRECHARGE FAIL
T4 PRECHARGE CHARGE ENABLED PRE ALL UNDER VOLT
T5 PRECHARGE DISCHARGE ENABLED PRE ALL OVER VOLT
T6 PRECHARGE ALL ENABLED PRE NONE PACK PRECHARGE FAIL
UNDER VOLT
OVER VOLT
T7 CHARGE ENABLED INIT NONE PACK ENABLE
STANDALONE
T8 CHARGE ENABLED ALL ENABLED PRE NONE UNDER VOLT
OVER VOLT
T9 DISCHARGE ENABLED INIT NONE PACK ENABLE
STANDALONE
T10 DISCHARGE ENABLED ALL ENABLED NONE UNDER VOLT
OVER VOLT
T11 CHARGE ENABLED PRE CHARGE ENABLED NONE BMS CRITICAL SAFETY EVENTS
T12 DISCHARGE ENABLED PRE DISCHARGE ENABLED BMS CRITICAL SAFETY EVENTS
T13 ALL ENABLED PRE ALL ENABLED BMS CRITICAL SAFETY EVENTS
T14 ALL ENABLED INIT PACK ENABLE
STANDALONE
T15 ALL ENABLED CHARGE ENABLED UNDER VOLT
T16 ALL ENABLED DISCHARGE ENABLED OVER VOLT

LED Output

This section describes the behaviour of the LED output of the Front Panel Connector.

Currently LED 1 and LED 2 of the Front Panel Connector are not in use.

LED 3 of the Front Panel Connector will either remain solid (“Stays ON”) or flash a specific number of times over a 5 second interval. The status of the BMS can be determined by counting the number times LED 1 flashes between each pause over the 5 second interval. The table below lists the meaning of each flash count.

Flash Count Label Description
9 Sense error There is an active SENSE ERROR event. The BMS cannot communicate with the cell measurement nodes
8 Critical Over Volt There is a latched CRITICAL OVER VOLT event. The BMS has detected that the critical over voltage threshold has been exceeded
7 Critical Under Volt There is a latched CRITICAL UNDER VOLT event. The BMS has detected that the critical under voltage threshold has been exceeded
6 Critical Over Volt There is a latched CRITICAL OVER CURRENT event. The BMS has detected that the critical over current threshold has been exceeded
5 Over Temp There is an active OVER TEMP event. The BMS has detected that the over-temperature threshold has been exceeded
4 Under Temp There is an active UNDER TEMP event. The BMS has detected that the under-temperature threshold has been exceeded
3 Precharge Fail There is an active PRECHARGE FAIL event. The BMS has detected that the precharge voltage threshold has not been reached
2 Balancing There is an active BALANCING event. The BMS has detected that the balance voltage threshold has been exceeded. This indicates at least 1 cell is currently being balanced
1 Disabled The BMS is in either the INIT or ERROR state and the BMS outputs are all off. Meaning that the battery cannot charge or discharge. This is usually due to a communication timeout on the BMS Switches CAN ID or the BMS is not in STANDALONE mode.

Configuration

The firmware of the Prohelion 48V BMS allows for the configuration of several values, thresholds, modes, and calibration values. This section documents each configuration parameter and the impacts of associated parameter on the system.

The resolution (scale factor) is maximum precision in which the value can be stored as SI units. The resultant integer value is the actual threshold (in Volts, Amps, or ℃) multiplied by the scale factor. For example, 3.600 Volts would equate to an integer value of 3600 being sent via CAN bus. This mathematical operation is automatically handled by Profinity.

ID Parameter Type Resolution (scale) Description
0x33 CAN - Bitrate Uint16 - The CAN bus bitrate selection value. This should be an integer value between 0 and 5:
- 0: 50kbps
- 1: 100kbps
- 2: 125kbps
- 3: 250kbps
- 4: 500kbps
- 5: 1000kbps
0x34 CAN - Base ID Uint 16 - The base CAN ID for the BMS. This should be a value between 0 and 1,792. For example, a base CAN ID of 0x600 (in hex) would be 1,536
0x35 CAN - Switches ID Uint16 - The CAN ID on which the BMS receives the Switches message. See communication section
0x3B BMS - Modes Config Uint16 - A set of 16 bits used to toggle different features of the BMS. The result is a bitwise OR of each feature:
- 0x00: Not Enabled
- 0x01: Standalone
- 0x02: Opportunistic Balancing (Not Implemented yet)
- 0x04: Victron Integration (when not using the parallel pack control unit)
For example, to enable both Standalone and Victron Integration set the value to 0x05 (0x01 + 0x04)
To disable all modes set the value to 0x00
0x39 Cell - Under Voltage Threshold (V) Uint16 0.001 (1000) The cell voltage threshold at which the BMS triggers an UNDER VOLT event.
0x3F Cell - Critical Under Voltage Threshold (V) Uint16 0.001 (1000) The cell voltage threshold at which the BMS triggers a CRITICAL UNDER VOLT event.
0x38 Cell - Over Voltage Threshold (V) Uint16 0.001 (1000) The cell voltage threshold at which the BMS triggers an OVER VOLT event.
0x40 Cell - Critical Over Voltage Threshold (V) Uint16 0.001 (1000) The cell voltage threshold at which the BMS triggers a CRITICAL OVER VOLT event.
0x3A Cell - Balancing Threshold (V) Uint16 0.001(1000) The cell voltage threshold at which the BMS enables balancing if the minimum and maximum cell voltages are more than 5mV apart. Only cell which are 5mV higher than the minimum cell voltage will be balanced.
0x3D Temp - Over Temperature Threshold (°C) Int16 0.1(10) The temperature threshold at which the BMS triggers an UNDER TEMP event.
0x3E Temp - Under Temperature Threshold (°C) Int16 0.1(10) The temperature threshold at which the BMS triggers an OVER TEMP event. This threshold only applies while charging. When discharging, the threshold is 0°C
0x42 Pack - Precharge Voltage Delta (V) Uint16 0.001 (1000) The pack voltage threshold at which the BMS triggers a PACK PRECHARGE FAIL event.
0x43 Pack - Precharge Timeout (S) Uint16 0.1(10) The time which the BMS state machine waits in the PRECHARGE state before moving to ERROR.
0x41 Pack - Over Current Threshold (A) Uint16 0.01 (100) The pack current threshold at which the BMS triggers a CRITICAL OVER CURRENT event. This is triggered by positive and negative current.
0x4D Pack - Capacity (Ah) Uint16 0.01 (100) The capacity of the pack which is used to estimate the State of Charge.
0x4E Pack - SoC(%) Uint16 0.01 (100) The SoCof the pack. This can be manually configured by the end user to a value if desired to override the current SoCestimation.
0x44 Calibration - Current Offset Int16 - The zero-axis offset calibration value for the current measurement. This value can be adjusted so that the reported current is zero when the BMS is disengaged. This should typically be a value of less than 50.
0x45 Calibration - Current Scale Uint16 - The scale calibration value for the current measurement. This value can be adjusted so that the reported current matches a measured current. This should typically be a value of around 10,000.
0x47 Calibration - Voltage Scale Uint16 - The scale calibration value for the load voltage measurement. This value can be adjusted so that the reported load voltage matches a measured voltage. This should typically be a value of around 10,000.
0x48 Node - count Uint16 - The number of cell measurement nodes being used by the BMS. For 48V BMS (16S), this should always be 2.
0x36 Node - Parallel Count Uint16 - The number of cell measurement nodes in parallel. For 48V BMS (16S), this should always be 1.
0x49 Node0 - Cell Count Uint16 - The number cells in use on the first cell measurement node. For 48V BMS (16S), this should always be 8. The minimum is 4.
0x4A Node0 - Temp Count Uint16 - The number temperature inputs in use on the first cell measurement node. The maximum is 8 and the minimum is 0.
0x4B Node1 - Cell Count Uint16 - The number cells in use on the second cell measurement node. For 48V BMS (22S), this should always be 11. The minimum is 4
0x4C Node1 - Temp Count Uint16 - The number temperature inputs in use on the first cell measurement node. The maximum is 4 and the minimum is 0.

BMS Modes:

This section explains the different features that can be enabled using the BMS Modes configuration parameter.

Standalone Mode: Standalone mode simply enables the BMS to transition from INIT state into PRECHARGE state automatically upon start-up. See T2 of the BMS transition table.

NOTE: When using a Prohelion Parallel Pack Controller device, this mode should be disabled.

Opportunistic Balancing Mode: This feature has been temporarily disabled in favour of a more simplistic threshold based balancing algorithm.

Victron Integration Mode: Victron Integration mode enables the CAN bus communication required for the BMS to integrate with Victron inverters using the DVCC protocol. This requires the use of a Victron Cerbo GX to connect the BMS and the Victron inverter.

NOTE: When using a Prohelion Parallel Pack Controller device, this mode should be disabled.