Binding settings reference

A binding is an object in the bind list of a component. A bind list can hold several bindings, one for each property that the data drives. This page is a lookup table of every binding setting, and each group links to the page that explains it.

dashboard:
  items:
    - row:
        items:
          - readouts:
              items:
                - readout:
                    label: "DSP Temperature"
                    unit: "°C"
                    bind:
                      - target: "value"
                        source: "DBC/DspBoardTempMeasurement/DspBoardTemp"

Source and target

The schema requires only source, and every other setting is optional. The target names the property that the value updates, so set it on every binding that is meant to change what a component shows.

Setting Type Default Description
source string None The tag path of the tag to bind (for example DBC/BusMeasurement/BusVoltage or Properties/StatusColourText). Refer to Binding source paths
target string value The component property to update (for example value, label, enabled, visible, color). A binding with a target that the component does not accept is ignored. Refer to Conditional styling

Transform

These settings change the value before the component shows it, and Transform and map values shows each one in use.

Setting Type Default Description
toType string None Data type conversion (number, string, boolean or string\|number). Not set means no conversion, and the value passes through unless the component sets its own type for that target. A lamp enabled target is always read as a boolean.
gain number None Multiplicative scaling factor, applied before offset. Not set means no scaling (1)
offset number None Additive offset, applied after gain. Not set means no offset (0)
invert boolean None Flips a boolean. For a number, gives 1 for 0 and 0 for any other number. It has an effect only when toType is set. Not set means not inverted
mapToText object None Text mapping configuration. Refer to Text mapping

Mode

These settings decide whether the binding reads the latest value or a window of history, and Binding modes explains them.

Setting Type Default Description
seriesMode string instant instant (the default), timeSeries, or timeSeriesDelta. A chart plots a series of samples when this is timeSeries or timeSeriesDelta. The Visual Editor shows the window settings only for these two modes
start string -10m Start of the time window, relative to now, such as -10m, or an ISO 8601 instant. When stop is set and this is omitted, the window starts 10 minutes before the stop time
stop string None End of the time window, relative to now, where 0m is now. When omitted, the window ends at now
aggregationWindow string None Length of each interval used for the older values that come from the designated historian (for example 1m). When omitted, the interval is 1 second for a window up to 1 hour, 10 seconds up to 24 hours, and 1 minute for longer windows.
aggregationFunction string max How each interval is reduced for the older values from the designated historian: max (the default), mean, min, last, first, sum, or count

Profinity reads the recent part of a window from memory, and the older part from the designated historian, as described in Live and past data. Aggregation applies only to the values from the historian, and values from memory are not aggregated.

Chart only

Setting Type Default Description
stackScale boolean None Gives this series its own Y axis. Not set means no separate axis
seriesType string None line, bar, or scatter, overriding the chart type for this series. Not set means the chart type

The Component reference describes the chart, the targets of each component, and the other components. The Motor controller dashboard example shows a complete dashboard.